Scientific Reports volume 14, Article number: 13423 (2024) Cite this article 500 Accesses Metrics details To effectively control the dust generated by coal mining operations, a new type of cyclonic

Scientific Reports volume 14, Article number: 13423 (2024) Cite this article

500 Accesses

Metrics details

To effectively control the dust generated by coal mining operations, a new type of cyclonic pneumatic mist curtain dust control device was developed. Using CFD software, numerical simulations were conducted on the internal airflow velocity field, the exit velocity of the cyclonic pneumatic mist curtain, and the mist droplet particle field of the curtain. Experiments were carried out to measure the spray coverage, droplet size, and the dust control performance of the model device. The results indicate that when the water pump supply pressure is 8 MPa, the fan supply wind speed is 12 m/s, and the nozzle installation angle is 75 degrees, the cyclonic pneumatic mist curtain dust control device model operates under optimal conditions. The effective coverage of the cyclonic mist curtain is 380 × 3300 mm, fully suppressing dust generation on one side of the curtain. An optimal dust removal distance of about 90 cm was determined. After installing the cyclonic pneumatic mist curtain dust control device, the average dust reduction efficiency for respirable dust reached 91.07%, and the overall dust reduction efficiency achieved 93.34%.

Dust production in fully mechanized mining faces typically ranges from 20 to 38%1,2,3. Often, the total dust concentration and respirable dust concentration in heading faces significantly exceed relevant national standards, such as the Coal Mine Safety Regulations4,5. As the level of coal mine mechanization continues to advance, both the mines and working faces are evolving toward larger scale, higher intensity, and increased mechanical automation, consequently leading to a rise in dust concentration in fully mechanized mining faces and other working environments6,7,8,9,10. This escalation situation poses a significant risk to the safety of coal mine operations and the health of the workers11,12,13.

In recent years, a significant decrease in the overall death toll from coal mine production accidents underscores the substantial and consistent improvements in mine safety14,15. By the year 2020, China reported 904,000 cases of occupational pneumoconiosis, with Coal Workers’ Pneumoconiosis (CWP) is accounting for more than 50% of these cases. Alarmingly, the fatality rate for CWP stands at approximately 2000 deaths annually, surpassing the number of fatalities from coal mine safety accidents16,17,18. The primary factor behind this high prevalence of mine pneumoconiosis cases is the inadequate attention given to occupational pneumoconiosis in coal and other enterprises, along with the ineffectiveness in controlling respirable dust emissions during coal mine production19,20,21. Figure 1 displays the death rate cases attributed to millions of tons of coal production-related accidents in China from 2005 to 2023, while Fig. 2 illustrates the level of dust pollution during the excavation process.

Mortality rate of million tons of coal in mine accidents from 2005 to 2023.

Dust generation during the excavation process.

In the subterranean operations of a coal mine, a substantial amount of dust is generated during the excavation process, posing a significant pollution threat to the heading face22,23. The mitigation of dust pollution in underground mine heading faces has become a prominent and complex challenge that experts worldwide are closely monitoring. Currently, scholars from various countries have examined dust control technology for heading faces from various perspectives. Ye et al. employed the LES-VOF droplet collision probability algorithm, combined with other scholars' research on the generation and migration patterns of dust, to discuss the effects of spray pressure and effective spray distance on dust reduction. They found that spray pressures exceeding 5 MPa could achieve dust reduction efficiencies of around 90%24,25. Xu et al. used three-dimensional computational fluid dynamics simulations coupled with airflow to study the dust suppression effects of a cyclone separator dust control device, discovering that the optimal dust reduction occurred when the inlet wind speed was increased from 15 to 25 m/s26. Nie et al. researched the optimal air volume for dust curtain suppression technologies in controlling dust pollution dispersion, finding that the best suppression efficiency of 85% was achieved with an air volume of 90 m3/min27. However, these studies also noted challenges, such as the need for high pressures in high-pressure spraying to achieve effective dust control, substantial air pressures required for dust curtain devices, generally poor performance on fine particulates, and inflexible installation of the devices28,29. Currently, several studies have demonstrated that a combination of air curtain dust control and high-pressure spray dust control technology is a highly efficient means of effectively managing coal dust30,31,32,33,34,35,36. These studies encompass the optimization of working parameters for air curtain dust control devices to enhance their ease of installation and mobility, the secondary crushing of mist droplets, and improvements in capturing dust with small particle sizes37,38. Nonetheless, the existing dust control devices are unable to keep pace with the heading's tunnelling progress for continuous dust reduction operations39,40.

To address the aforementioned challenges, we have integrated wind curtain dust removal technology with high-pressure spray dust reduction technology. This device features a simple structure and operates with a low air volume, utilizing underground air ducts to supply air. It covers a large area, avoiding the direct use of fans, thereby enhancing the versatility of its installation. This approach creates a water fog curtain that fully envelops the dust source at the cutting head, effectively sealing and capturing respirable dust and further enhancing the underground working conditions in the coal mine. Through a combination of numerical simulations and experimental measurements, we've analyzed the formation mechanism of the vortex pneumatic fog screen and the process of combining wind and fog. As a result of these efforts, we have developed a vortex pneumatic fog screen dust control device that can operate simultaneously with the heading, improving dust control during excavation.

To address the dust pollution in the aforementioned fully mechanized mining face, we propose the using a vortex pneumatic fog screen dust control device. As illustrated in Fig. 3, strategically positioned nozzles on the cutting head and evenly distributed along the air tube at specific angles work in unison. The droplets passing through the vortex air duct assist in creating an interconnected network of spiral fog curtains that effectively seal off the roadway and capture dust particles. Furthermore, the central region of the fog curtain generates a negative pressure zone directed towards the center of the inner annular air duct. This negative pressure compels the dusty airflow to interact once more with the fog curtain, leading to a secondary dust settling effect.

Location of pneumatic vortex spraying curtain.

As depicted in Fig. 3, the primary components of the pneumatic vortex fog screen dust control device developed in this study include the annular air tube, high-pressure air flow ejector, and nozzles. The main equipment is introduced below:

Annular air duct:

The annular air duct functions as the transitional segment between the air inlet duct and the high-pressure air flow deflector. Its purpose is to partition and direct the airflow for the high-pressure air flow ejector.

High-pressure airflow ejector:

The high-pressure air flow ejector consists of air outlets uniformly distributed on the inner surface of the annular air tube. These outlets guide the airflow inwards, crucial for generating the high-speed air jet. The high-pressure air flow ejector, uniformly positioned along the inner wall of the annular air tube, expels impacting airflow with tangential velocity components. This process ultimately forms a rotating air curtain wall with vortex impact momentum ahead of the air outlet.

Spray nozzles:

The nozzles convert the pressure and water pressure energy within the annular pipe into kinetic energy. These annular nozzles serve as the pivotal elements for high-pressure spraying and serve as the primary points for atomization. The high-pressure nozzle model is CC-L, featuring an orifice diameter of 0.79 mm, a flow rate of 0.3 L/min, and an operating pressure of 8 MPa.

The outlet velocity of the device, the airflow velocity field within the device, and the droplet particle field of the vortex pneumatic fog screen underwent numerical simulation using the control single variable method and CFD simulation software. The objective was to analyze the impact of various parameters on the atomization efficiency of the device, providing a theoretical foundation for vortex pneumatic fog screen dust control technology.

Turbulent flow is a common natural phenomenon. In most engineering scenarios, fluid flow is predominantly turbulent, with turbulence characteristics playing a significant role. In turbulent flow, the fluid exhibits disorder and chaos, even under constant boundary conditions, resulting in unpredictable flow characteristics such as varying velocities. As such, it becomes essential to simulate the airflow velocity distribution within the air duct generator41,42,43.

The Kelvin–Helmholtz (K–H) model is widely employed in the study of gas–liquid two-phase flow44. In this study, we utilized the incompressible k-ε turbulence model and a particle tracking model based on the K–H model to simulate the two-phase flow field in a vortex pneumatic fog curtain using CFD numerical simulation software. The governing equations of the K–H model describe the vortex spray and the secondary breakage of droplets within the vortex aerodynamic fog screen.

where ΩKH is the maximum frequency, ΛKH is the growth wavelength; the Weber number of the liquid is \(We_{g} = \frac{{\rho_{g} U_{r}^{2} L}}{\sigma }\); Ur is the relative velocity difference between the liquid phase and gas phase; L is the feature length; σ is the surface tension coefficient of the liquid; ρg and ρf are the densities of the gas phase and liquid phase, respectively; Z is the Unsaiğ number, \(Z = \frac{{\sqrt {We_{l} } }}{{Re_{l} }}\); The liquid Reynolds number is \(Re_{l} = \frac{{\rho_{f} U_{r}^{2} r}}{\mu }_{f}\); \(\mu_{f}\) is the viscosity of the liquid; and \(T = Z\sqrt {We_{g} }\) is the Taylor number.

During the crushing process, the atomization rate of particles is calculated as follows:

When rKH is the radius of Kmuri H broken particles, the shear force is \(\tau_{{{\text{KH}}}} = \frac{{3.788{\text{B}}_{{{\text{KH}}}} }}{{{\Lambda }_{{{\text{KH}}}} {\Omega }_{{{\text{KH}}}} }}\). BKH is the empirical constant < 10, indicating that the atomization time of particles. The smaller the value, the earlier the decomposition time, and the faster the atomization speed. Then, the radius of the subdroplet produced when the mother droplet with a radius equal to rp breaks is

In the formula, B0 is a constant, taking 0.61, and Ur is the velocity difference between the gas and liquid phases.

The numerical simulation of the wind flow field employs the standard k-epsilon turbulence model, renowned for its high accuracy in calculating reverse pressure gradient flow fields. The Reynolds number associated with spiral spray dust control technology is substantial, with the inertia force significantly outweighing the fluid's viscous force.

The physical model of the three-dimensional scroll spray generator has been created using CFD simulation software. In real working conditions, it's observed that when the number of nozzles is less than 5, the vortex spray generator cannot generate a complete fog screen. Conversely, when the number of nozzles exceeds 5, the sprays produced by the vortex spray generator start interfering with one another, making it challenging to establish an effective fog curtain. Therefore, the high-pressure spray ring is comprised of five high-pressure nozzles, each positioned 72° apart. The airflow channel measures 2000 mm in length, 120 mm in width, and 150 mm in height, with the vortex spray head having a radius of 0.23 m.

Meshing is a crucial aspect of numerical simulation as it directly impacts the accuracy and precision of the results, potentially leading to errors in numerical calculations. Figure 4 illustrates a physical model grid simulation diagram of the vortex pneumatic fog screen dust control device.

Grid drawing of vortex generator.

Grid independence is verified by comparing the computational results at different mesh densities. If the results stabilize with mesh refinement, the simulation can be considered grid-independent. Figure 5a shows the variation in the simulated wind speed at the head of the vortex airflow for three different meshing schemes. It is evident that Scheme II produces results that are not significantly different from those obtained with an ultra-fine mesh, thus Scheme II has been selected for the numerical simulation’s mesh division. This simulation utilized a total of 2,456,938 mesh elements, with an average element size of 0.6745 and a minimum size of 0.0374. The element quality distribution, depicted in Fig. 5b, falls within the range of 0.5 to 1, confirming the reliability of the mesh quality. Additionally, the correctness and reliability of the mesh division can be further validated through experimental verification.

Mesh Division Results3.3 Model condition setting.

According to the actual working conditions of the vortex pneumatic fog screen dust control device and the field data measurement, the relevant boundary conditions are set by using COMSOL software, as shown in Table 1.

We measured the coverage area of the fog screen produced by the vortex pneumatic fog screen device. The experimental setup included a vortex fog curtain generating device consisting of a high-pressure spraying device, a centrifugal fan, a metal air supply pipe, and a vortex air flow generator. During the experiment, a thermal anemometer was used to measure the vortex wind speed. In this experiment, we employed the controlled variable method. To enhance the device's capability to capture small particle-size dust, we increased the water supply pressure when feasible, opting for a novel high-pressure spray system with a pressure setting of 8 MPa. We regulated the fan's blowing speed using a frequency converter and conducted tests to assess the spray coverage at various fan angles (ranging from 30° to 105°) at different wind speeds (0 m/s, 40 m/s, 60 m/s, 80 m/s, 100 m/s, and 120 m/s). Figure 6 shows a schematic diagram of the experimental platform.

Schematic of experimental platform.

Building upon the experiment regarding the coverage area of the vortex pneumatic fog screen, we maintained the pressure of the high-pressure spraying device at 8 MPa. We conducted tests to measure the spray diameter of the corresponding fan at a 75° angle and compared it with the performance of a traditional high-pressure spray (with the fan's wind speed set to 0 m/s). The experiment employed a Fraunhofer diffraction principle particle size analyzer for testing, and the droplet size testing platform is illustrated in Fig. 7.

Droplet size testing platform.

The detailed experimental protocol is as follows:

Instrument calibration: The emitted laser beam must form a uniform, regular green spot at the receiver end. The beam should pass through the center of the Fourier mirror and the collimating lens and be perpendicular to the collimating lens.

Turn on the laser particle size analyzer and allow it to warm up for 10 to 15 min. Start the computer and launch the particle size analysis software.

Select "Background Measurement" from the "Test" menu, accumulate ten background measurements, then proceed to the energy spectrum test.

Adjust the fan speed and vary the spray distance to conduct control experiments. By adjusting the distance between the cyclonic pneumatic generator and the particle size analyzer, record the experimental data on changes in droplet size of the cyclonic pneumatic mist curtain at different distances. Conduct ten sets of experiments for each group and calculate the average data to ensure the accuracy of the final results.

In order to investigate the dust reduction effectiveness of the vortex pneumatic fog screen dust control device within an underground driving roadway, we constructed an experimental shed on the ground. This shed has dimensions of 4 m in length, 3 m in width, and 2.5 m in height, serving as a simulation roadway. At the far end of this simulation roadway, dust emissions were simulated and contained, while the opening at the near end was utilized for testing the ventilation and dust control performance. The coal samples used in the experiment were bituminous coal from Wangjialing Coal Mine, owned by China Coal Huajin Group. To commence the experiment, coal blocks were crushed and ground into fine particles ranging in size from 60 to 2500 mesh (5.9 μm to 247 μm). This pulverized coal was then fed into a custom-made dust generator, which continuously produced dust at a rate of 10 g per second. Once the entire space inside the experimental shed was filled with dust, we activated the vortex pneumatic fog screen dust control device. The nozzle was set at a 75° installation angle, the fan operated at a wind speed of 12 m per second, and the water supply pressure was maintained at 8 MPa. Within the transverse section, three dust detection points were established, as illustrated in Fig. 8, which displays the layout of these survey points.

Survey point layout.

The dust concentration of the measuring point before and after opening the vortex pneumatic fog screen dust control device is measured, and the dust reduction efficiency of the vortex pneumatic fog screen dust control device is calculated according to Formula 5:

In the formula, the average dust reduction efficiency is \(\eta\)—dust prevention measures, %. c0—average dust concentration after opening the vortex pneumatic fog screen, mg/m3. c1—-average dust concentration before opening the vortex fog screen, mg/m3.

We conducted a simulation to analyze the airflow velocity field within the vortex generator. In order to prevent interference from the roadway airflow with the formation of the vortex pneumatic fog curtain during the actual operation of the device, it was necessary to set a higher wind speed for the pneumatic fog curtain. Based on the actual working conditions and the stable long-term operation capability of the centrifugal fan, we set the inlet wind speed to 12 m/s. Figure 9 illustrates the velocity distribution of the simulated airflow in different sections of the vortex generator, with the gradient zone on the right side of the numerical simulation chart representing the velocity. As depicted in Fig. 9, the inlet speed of 12 m/s results in an outlet wind speed of 30 m/s. Figure 10 presents the external wind flow field of the vortex generator.

Velocity distribution of air duct.

External air flow field of the device.

As observed in the visual representation, the vortex airflow projects forward in a vortex-shaped manner, and its range progressively expands, gradually shaping a rotating wind curtain. This closely mirrors what was observed during the experimental phase. Figure 10 reveals that the airflow diminishes rapidly once it escapes through the 32 slits of the louvers. Within a distance of 0.3 m, the airflow velocity decreases to 1.2 m per second, and at 0.8 m, a minimal amount of airflow is directed along the x-axis.

We conducted a simulation to analyze the outlet velocity of the vortex pneumatic fog screen. In this simulation, the section boundary type for the airflow entering the calculation area was set as a velocity inlet, while the outlet was designated as a pressure outlet. The nozzle was positioned along the positive x-axis direction, and the particle type was specified as liquid drops, with water as the material and a spray pressure of 8 MPa.

As depicted in Fig. 11, the device's outlet velocity progressively transforms into a vortex-like fog screen once it surpasses 10 m/s. Furthermore, it is evident that the thickness of the vortex spray ring diminishes as wind speed increases. However, the cross-sectional area expands, resulting in greater spray coverage. It's important to highlight that for enhanced dust capture efficiency, it is advantageous to have a higher spray speed, allowing fog droplets to collide more vigorously with dust particles. Based on practical considerations, it was observed that when the airflow velocity of the vortex spray head reaches 35 m/s, it generates increased vibrations in the airflow channel. To ensure the device's long-term operational stability, an outlet velocity of 30 m/s has been defined as the optimal wind speed for this device. Two exit velocities were examined: 10 m/s and 30 m/s.

Droplet trajectory diagram at exit velocities of 10 m/s and 30 m/s.

Following the adjustment of nozzle angles, we conducted simulations to observe the droplet particle spray process and obtain information regarding the range of droplet sizes and fog screen coverage. For these simulations, we maintained a wind speed of 30 m/s and an initial spray velocity of 30 m/s. Three nozzle angles, specifically 60°, 75°, and 90°, were chosen for the simulation. The results of the droplet particle field simulations for these three nozzle angles are presented in Figs. 12, 13 and 14. The numerical simulation charts include a gradient band on the right side to indicate the droplet sizes.

Trajectory diagram of vortex spray particles at nozzle angle of 60°

Trajectory diagram of vortex spray particles at nozzle angle of 75°

Trajectory diagram of vortex spray particles at nozzle angle of 90°

As illustrated in Figs. 12, 13 and 14, when the nozzles are installed at a 60° angle, the mist curtain moves forward in a circular shape with a diameter of 2.6 m, and the effective spray distance is 0.4 m, 20 s post-initiation. The droplet sizes range from 3 to 12 μm. Notably, the atomization effect of droplets produced by the vortex generator surpasses that of traditional high-pressure spraying. As the spray distance increases, the droplet size gradually decreases, with most droplets disappearing beyond a 0.4-m spray distance. Conversely, when the nozzles are set to a 75° angle, the effective spray distance remains at 0.4 m, with the mist curtain advancing in a circular shape with a diameter of 2.6 m, and droplet sizes roughly between 3 and 12 μm. At a spray distance of 0.2 m, the droplet diameter is approximately 12 microns. Beyond a spray distance of 0.4 m, the primary droplet diameter stabilizes at 6 μm, with most droplets disappearing after exceeding this threshold. This trend indicates that droplet size diminishes with increasing spray distance. It is noteworthy that when the nozzle angle is set to 90°, both the coverage area and spray distance slightly decrease compared to the 75° nozzle angle setting, with the mist curtain moving forward in a circular shape with a diameter of 2.5 m and an effective spray distance of 0.35 m. Additionally, high-speed airflow not only aids in the secondary breakup of droplets but also assists in capturing and controlling fugitive dust particles through generated negative pressure. This mechanism enhances dust suppression efficiency as smaller water droplets can more effectively combine with airborne dust particles. Since the high-speed airflow does not directly blow onto the dust source, its primary function is to facilitate droplet breakup, thereby preventing secondary dust generation. While ensuring effective dust reduction, it is essential to moderately reduce the concentration of mist to prevent an overly humid work environment. Excessively dense mist can also decrease visibility in the workplace, impacting safety and operational efficiency.

As indicated in Table 2, showcasing the spray coverage under various fan speeds and nozzle installation angles, Fig. 15 depicts the changes in the effective spray distance of the fog screen concerning wind speed and spray angle, while Fig. 16 illustrates the alterations in fog screen coverage with respect to wind speed and spray angle. After analysis, it was found:

When the fan operates at a wind speed of 0 m/s, it is essentially equivalent to traditional high-pressure spray. In this scenario, when the spray angle increases to 90°, the effective spray distance expands, while the thickness and height of the fog curtain undergo minimal changes. These findings suggest that for traditional high-pressure spray, the maximum fog curtain coverage is achieved with a 90° nozzle angle.

When the fan is utilized for vortex spray and the nozzle angle ranges from 30° to 75°, the experimental results align with the simulation results. As the fan's wind speed increases from 0 to 12 m/s, the fog curtain becomes thinner with increasing wind speed, while its width and height gradually increase. Figure 17 illustrates the spray effect with a 75° nozzle angle when the fan operates at wind speeds of 0 m/s and 12 m/s.

With the nozzle angle set at 75° and the fan's wind speed reaching 12 m/s, the fog screen coverage area measures 380 mm in width and 3300 mm in height. When the nozzle angle shifts to 90°, the fog screen coverage decreases compared to the 75° angle, and the smallest coverage is observed with a 105° nozzle angle. Therefore, when the nozzle installation angle is 75° and the fan operates at 12 m/s, the vortex spray achieves maximum fog screen coverage.

When the fan's wind speed reaches 12 m/s, the wind speed at the vortex spray head outlet, as measured by the anemometer, is 29.7 m/s, which is closely aligned with the experimental result of 30 m/s. This validation demonstrates the accuracy of the simulation data.

Variation law of effective spray distance of fog screen.

Variation law of fog screen coverage.

Spray effect picture at nozzle angle of 75° and wind speeds of 0 m/s and 12 m/s.

In spray particle size testing, d50 and d90 are crucial parameters that describe the distribution of particle sizes. The d50 value is an indicator of the central tendency of spray particle sizes, typically used to describe the median particle size. The d90 value is used to assess the distribution of larger particles within the spray, indicating the extent to which larger particles are present. We conducted spray experiments using the vortex pneumatic fog screen dust control device under two conditions: with the water supply pressure set to 8 MPa, the nozzle installation angle at 75°, and the fan operating at wind speeds of 12 m/s and 0 m/s. The variations in droplet diameter with distance are presented in Table 3. Based on the data in Table 3, we compared the droplet sizes produced by the vortex pneumatic fog screen, as depicted in Fig. 18, with those generated by traditional high-pressure spray.

Comparison of particle size between vortex pneumatic fog screen and traditional high-pressure spray.

As depicted in Table 3 and Fig. 18, the droplet size of the vortex pneumatic fog screen and traditional high-pressure spray increases with increasing injection distance, but the droplet diameters D50 and D90 of the vortex pneumatic fog screen are always shorter than those of the traditional high-pressure spray. This is because the vortex air flow contributes to the secondary breakup of liquid droplets. A more detailed explanation is as follows: the atomization breaking process of the jet can be summarized as the disturbance breakup caused by the turbulent vortex, which is mostly the formation process of the liquid core. According to the division of the jet spray field, the atomized jet region from the nozzle can be divided into the dense zone and the dilution zone, and the spray jet region is divided as shown in Fig. 19. After the droplet is ejected, the droplet is broken by the impact and shear of the jet gas and is ejected in the form of a liquid wire or liquid line. Due to air disturbance, the droplet expands sharply until it breaks, and fine droplets are formed after a breakup. These droplet particles are impacted by the vortex airflow generated by the vortex fog curtain generator, the force and acceleration of the droplets in the dilution zone, secondary atomization such as collision or fragmentation and merging between the droplets, and further secondary breakup that occurs to form new and finer droplet particles.

Division of spray jet region.

Notably, within a spray distance of 60 cm, the vortex pneumatic fog screen is close to the traditional high-pressure spray droplet size D90. When the spray distance is 60–120 cm, there is a great difference in droplet size D90 between them. This is due to the gradual formation of vortex airflow after 60 cm and the gradual enhancement of the crushing effect on droplets. When the spray distance is greater than 120 cm, the difference between droplet sizes D90 and D50 decreases. Therefore, it can be seen that the best distance for secondary crushing of droplets by vortex air flow is 60–120 cm.

It's worth noting that the results show that the smaller the droplet diameter, the better the capture effect of respirable dust45. When the spray distance of the vortex pneumatic fog screen is greater than 105 cm, D90 is also greater than 100 μm. At the same time, considering the best distance of secondary crushing of liquid droplets by vortex air flow and the capture effect of respirable dust, approximately 90 cm is selected as the best dedusting distance of the vortex pneumatic fog screen.

Analyzing the dust concentration test data in Table 4, we observe changes in dust concentration before and after activating the dust removal device, as illustrated in Fig. 20. Our analysis of the data reveals the following:

Dust concentration change.

Upon activation of the vortex pneumatic fog screen dust control device, its dust capture capability is significantly enhanced, particularly at the measurement point closest to dust source 1. The total dust concentration drops from 719.32 to 56.10 mg/m3, achieving a dust reduction efficiency of 92.20%. Furthermore, the concentration of respirable dust falls from 56.21 to 5.34 mg/m3, achieving a dust reduction efficiency of 90.5%. These figures provide compelling evidence that this device effectively prevents the dispersion of fine dust particles throughout the entire roadway.

It is worth noting that the dust reduction efficiency of traditional high-pressure spray systems typically ranges from 60 to 80%. However, upon activating the vortex spray dust control device, the dust reduction efficiency increases by 5% compared to traditional high-pressure spray. Evidently, the vortex spray dust control device exhibits a superior dust-capturing capacity. This enhanced performance can be attributed to the rotating nature of the spray within the vortex flow, leading to a spiral trajectory and an increased droplet-to-dust collision probability. Simultaneously, the high-speed movement of the vortex flow generates a negative pressure zone at its center, affecting the dust particles that escape initial capture along the fog curtain's periphery.

Additionally, activating the vortex pneumatic fog screen dust control device, there is a noticeable reduction in dust concentration. The average dust reduction efficiency for respirable dust stands at 91.07%, while the overall dust reduction efficiency reaches 93.34%. With the device in operation, it establishes a protective fog curtain, effectively separating the dust-generating surface from personnel on both sides of the fog curtain.

Based on a mature dust removal mechanism of wind curtains and high-pressure spray, combined with information from dust control studies by foreign and domestic scholars on coal mining faces, a set of vortex pneumatic fog screen dust control devices suitable for fully mechanized mining faces was developed. A simulation roadway was set up to test the dust removal performance of the device and compare it with CFD numerical simulations. The following conclusions can be summarized.

The utilization of vortex pneumatic fog screen dust control technology results in significantly smaller droplet sizes, notably when compared to traditional high-pressure spray methods. The device achieves its peak performance when the water supply pressure of the pump is set at 8 MPa, the fan operates at a wind speed of 12 m/s, and the nozzle is installed at a 75° angle. Under these conditions, the device generates a spiral fog curtain with a spray coverage of 380 mm in width and 3300 mm in height, effectively suppressing dust emissions originating from one side of the air curtain.

To optimize the device's dust removal capabilities, an approximate dedusting distance of 90 cm was chosen, taking into consideration the secondary crushing of liquid droplets by the vortex airflow and the device's efficacy in capturing respirable dust. This configuration yields a D50 droplet diameter of 32.564 µm and a D90 droplet diameter of 60.437 µm.

Based on the results of dust reduction experiments, the application of the vortex pneumatic fog screen dust control device results in an average dust reduction efficiency of 91.07% for respirable dust and 93.34% for all dust types. This technology enhances the distance over which droplets effectively collide with dust and captures escaped respirable dust through negative pressure entrainment.

Overall, the development of the vortex pneumatic fog screen dust control technology was achieved through a combination of theoretical analysis and experimental verification. Although the model device was continuously refined during the experiment, it has not yet been applied in the operational context of an underground fully mechanized heading face. Future research endeavors will focus on enhancing the device and conducting in-depth investigations into the impact of nozzle aperture diversity and the collision and condensation processes of simulated particles within the vortex fog screen dust control technology.

The data that support the findings of this study are available from the corresponding author, Ping Chang, upon reasonable request.

Bao, Q. et al. Preparation and characterization of a binary graft based, water-absorbing dust suppressant for coal transportation. J. Appl. Polym. Sci. https://doi.org/10.1002/app.47065 (2018).

Article Google Scholar

Wang, Z. et al. Respirable dust pollution characteristics within an underground heading face driven with continuous miner: A CFD modelling approach. J. Clean. Prod. 217, 267–283 (2019).

Article ADS Google Scholar

Li, S. et al. Removal of dust produced in the roadway of coal mine using a mining dust filtration system. Adv. Powder Technol. 30(5), 911–919 (2019).

Article Google Scholar

Niu, W. J. et al. Study of the microscopic mechanism of lauryl glucoside wetting coal dust: Environmental pollution prevention and control. J. Hazard. Mater. 412, 125223. https://doi.org/10.1016/j.jhazmat.2021.125223 (2021).

Article CAS PubMed Google Scholar

Zhang, H., Nie, W., Liang, Y., Chen, J. G. & Peng, H. T. Development and performance detection of higher precision optical sensor for coal dust concentration measurement based on Mie scattering theory. Opt. Lasers Eng. 144, 106642 (2021).

Article Google Scholar

Yan, J. Y. et al. Development and characterization of a dust suppression spray agent based on an adhesive NaAlg−gln−poly/polysaccharide polymer. Sci. Total Environ. 785, 147192. https://doi.org/10.1016/j.scitotenv.2021.147192 (2021).

Article ADS CAS Google Scholar

Cai, P. et al. Diffusion and pollution of multi-source dusts in a fully mechanized coal face. Process Saf. Environ. Prot. 118, 93–105 (2018).

Article CAS Google Scholar

Jia, M. et al. Migration law of respirable dust on a super-long fully mechanized double-shearer working face. Int. J. Min. Sci. Technol. 26(6), 1109–1115 (2016).

Article Google Scholar

Du, T. et al. CFD modeling of coal dust migration in an 8.8-meter-high fully mechanized mining face. Energy 212, 118616 (2020).

Article Google Scholar

Zhang, G. et al. CFD investigation on dust dispersion pollution of down/upwind coal cutting and relevant countermeasures for spraying dustfall in fully mechanized mining face. Adv. Powder Technol. 31(8), 3177–3190 (2020).

Article Google Scholar

World Health Organization. 9 out of 10 people worldwide breathe polluted air, but more countries are taking action. World Health Organization, Geneva, https://www.who.int/news/item/02-05-2018.

Liu, Q. et al. Research on tunnel ventilation systems: Dust diffusion and pollution behaviour by air curtains based on CFD technology and field measurement. Build. Environ. 147, 444–460. https://doi.org/10.1016/j.buildenv.2018.08.061 (2019).

Article Google Scholar

Bao, Q. et al. The preparation of a novel hydrogel based on crosslinked polymers for suppressing coal dusts. J. Clean. Prod. 249, 119343. https://doi.org/10.1016/j.jclepro.2019.119343 (2020).

Article CAS Google Scholar

Longzhe, J. The occupational hazards and strategy analysis of dust exposure in workplace in China. Saf. Secur. 41(01), 1–6 (2020).

Google Scholar

National Health Commission of the people's Republic of China. Circular on carrying out special control of dust and toxic hazards in mining, metallurgical, chemical and other industries. [EB/OL]. [2019–04–28]. http://www.gov.cn/zhengce/zhengceku/2019-10/08/content_5437005.htm

Tong, Y. et al. Survival and disease burden trend analysis of occupational pneumoconiosis from 1963 to 2020 in Shizuishan City. Zhonghua lao dong wei sheng zhi ye bing za zhi = Zhonghua laodong weisheng zhiyebing zazhi = Chin. J. Ind. Hygiene Occup. Dis. 40(5), 341–347 (2022).

CAS Google Scholar

Gang, Z. et al. Numerical analysis of dust pollution evolution law caused by ascensional/descensional ventilation in fully mechanized coal mining face based on DPM-DEM model. J. Environ. Chem. Eng. 10, 107732 (2022).

Article Google Scholar

Deng, Z., Tao, T. Y. & Qiao, Q. Socioeconomic status, occupational disease, and psychological well-being: Evidence from people with pneumoconiosis in China. Soc. Sci. 11, 28 (2022).

Article Google Scholar

Li, Y. et al. Time trends and future prediction of coal worker’s pneumoconiosis in opencast coal mine in China based on the APC model. BMC Public Health 18(1), 1010 (2018).

Article PubMed PubMed Central Google Scholar

Hoeflinger, W. & Laminger, T. PM2.5 or respirable dust measurement and their use for assessment of dust separators. J. Taiwan Inst. Chem. Eng. 94, 53–61 (2019).

Article CAS Google Scholar

Zhang, T. et al. Dust removal characteristics of a supersonic antigravity siphon atomization nozzle. Adv. Mech. Eng. 12(12), 168781402097768 (2020).

Article Google Scholar

Hua, Y. et al. The development and application of a novel multi-radial-vortex-based ventilation system for dust removal in a fully mechanized tunnelling face. Tunnel. Undergr. Space Technol. 98, 103253. https://doi.org/10.1016/j.tust.2019.103253 (2020).

Article Google Scholar

Xue, Q. Q. et al. Determining the optimal airflow rate to minimize air pollution in tunnels. Process Saf. Environ. Prot. 157, 115–130. https://doi.org/10.1016/j.psep.2021.10.039 (2021).

Article CAS Google Scholar

Deng, H. et al. Research of wet string grid dust removal vehicle and creation of dust control area on tunnel working face. Sci. Rep. 14(1), 8292 (2024).

Article CAS PubMed Google Scholar

Li, Z. et al. Research on the mechanism of coal wall fragmentation and dust production characteristics in the perspective of differentiated discrete elements. Sci. Rep. 14, 9312 (2024).

Article CAS PubMed PubMed Central Google Scholar

Nie, W. et al. Research on airborne air curtain dust control technology and air volume optimization. Process Saf. Environ. Protect. 172, 113–123 (2023).

Article CAS Google Scholar

Ren, S. et al. Research and development of vortex suction dedusting device based on multi-factor horizontal response surface method. J. Clean. Protect. 4, 140916 (2024).

Article Google Scholar

Xu, H. et al. Numerical simulation and experiment of dust suppression device of peanut whole-feed combine using computational fluid dynamics. Agriculture 13(2), 329 (2023).

Article Google Scholar

Ye, Y. et al. Research on the dust reduction by spraying law of fully mechanized face using a large-scale dust and droplet coupling model. Process Saf. Environ. Protect. 183, 875–889 (2024).

Article CAS Google Scholar

Jing, Y. & Yucheng, L. Researches on air curtain dust collection jet device. World SCI-TECH R&D 35(05), 591–593 (2013).

Google Scholar

Nie, W. et al. Research on air curtain dust control technology for environmental protection at fully mechanized working faces. Environ. Sci. Pollut. Res. 29, 43371–43384 (2022).

Article Google Scholar

Yucheng, Li., Zhi, Li. & Lun, G. Arrangement of air duct in tunneling working face based on the distribution laws of airflow and dust. J. China Coal Soc. 39(S1), 130–135 (2014).

Google Scholar

Weimin, C. et al. Numerical simulation on the flow field of swirling flow air curtain aspiration control dust in fully mechanized workface. J. China Coal Soc. 36(08), 1342–1348 (2011).

Google Scholar

Wen, N. et al. Experimental study on atomized particle size as affected by airflow disturbance at the heading face. J. China Univ. Min. Technol. 41(3), 378–383 (2012).

Google Scholar

Ronghua, L. et al. Study on flow ratio of blowing to drawing of rotational jet shield ventilation at tunneling working face. China Saf. Sci. J. 22(9), 133–139 (2012).

Google Scholar

Mezhericher, M. et al. Probabilistic hard-sphere model of binary particle–particle interactions in multiphase flow of spray dryers. Int. J. Multiphase Flow 43, 22–38 (2012).

Article CAS Google Scholar

Xu, C. W. et al. Multi-factor numerical simulation study on spray dust suppression device in coal mining process. Energy 182, 544–558. https://doi.org/10.1016/j.energy.2019.05.201 (2019).

Article Google Scholar

Yang, S. B. et al. Effects of spraying pressure and installation angle of nozzles on atomization characteristics of external spraying system at a fully-mechanized mining face. Powder Technol. 343, 754–764. https://doi.org/10.1016/j.powtec.2018.11.042 (2019).

Article CAS Google Scholar

Washino, K. et al. Direct numerical simulation of solid–liquid–gas three-phase flow: Fluid–solid interaction. Powder Technol. 206(1), 161–169 (2011).

Article CAS Google Scholar

Jun, Li. Research of dust-cleaning technique in driving face of rocky tunne. Coal Mine Mach. 34(02), 144–145 (2013).

Google Scholar

Ma, Q. X. et al. Effect of spraying on coal dust diffusion in a coal mine based on a numerical simulation. Environ. Pollut. 264, 114717 (2020).

Article CAS PubMed Google Scholar

Faschingleitner, J. & Flinger, H. W. Evaluation of primary and secondary fugitive dust suppression methods using enclosed water spraying systems at bulk solids handling. Adv. Powder Technol. 22(2), 236–244 (2011).

Article Google Scholar

Gang, Z. et al. Extended theoretical analysis of jet and atomization under high-presser spraying and collecting dust mechanism of droplet. J. Chongqing Univ. 35(03), 121–126 (2012).

Google Scholar

Wang, H. et al. Investigation on the atomization characteristics of a solid-cone spray for dust reduction at low and medium pressures. Adv. Powder Technol. 30, 903–910 (2019).

Article Google Scholar

Fang, X. et al. Effect of water–fog particle size on dust fall efficiency of mechanized excavation face in coal mines. J. Clean. Prod. 254, 120146 (2020).

Article Google Scholar

Download references

This work was funded by the National Natural Science Foundation of China (NO.51704146), the Natural Science Foundation of Liaoning Province (2020-MS-304)., China Scholarship Council. (No. 202308210373), Foundation of Liaoning Province Education Administration, JYTQN2023205.

College of Safety Science and Engineering, Liaoning Technical University, Fuxin, 123000, China

Shuaishuai Ren, Deji Jing, Yinuo Chen & Xiangxi Meng

Key Laboratory of Mine Thermodynamic Disasters and Control of Ministry of Education (Liaoning Technical University), Fuxin, 123000, China

Shuaishuai Ren, Deji Jing, Yinuo Chen & Xiangxi Meng

WA School of Mines: Minerals, Energy and Chemical Engineering, Curtin University, Kalgoorlie, WA, 6430, Australia

Shuaishuai Ren & Ping Chang

College of Safety and Emergency Management Engineering, Taiyuan University of Technology, Taiyuan, 03000, China

Shaocheng Ge

You can also search for this author in PubMed Google Scholar

You can also search for this author in PubMed Google Scholar

You can also search for this author in PubMed Google Scholar

You can also search for this author in PubMed Google Scholar

You can also search for this author in PubMed Google Scholar

You can also search for this author in PubMed Google Scholar

S.R.: Methodology, Software, Investigation, Data curation, Writing-original draft, Writing-review & editing. D.J.: Conceptualization, Writing-review & editing, Supervision. S.G.: Writing- review & editing. Y.C.: Software. X.M.: Writing review and editing. P.C.: Software, Writing-review & editing.

Correspondence to Deji Jing or Ping Chang.

The authors declare no competing interests.

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.

Reprints and permissions

Ren, S., Jing, D., Ge, S. et al. Experimental and numerical evaluation of the dust suppression efficiency of an innovative vortex pneumatic fog screen dust control device. Sci Rep 14, 13423 (2024). https://doi.org/10.1038/s41598-024-64140-2

Download citation

Received: 04 January 2024

Accepted: 05 June 2024

Published: 11 June 2024

DOI: https://doi.org/10.1038/s41598-024-64140-2